Part Number Hot Search : 
AWT6276R 7C126 SFT504 P8802 DF02S T1010DH 24C02N C1Z160B
Product Description
Full Text Search
 

To Download CF2-12 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 CF
NEW DUAL POWER AUTOMOTIVE RELAY
CF-RELAYS
Normally Normally Open Closed
22.5 .886
16.5 .650
FEATURES
* 7 Amp Steady/30 Amp Inrush current capability * Simple footprint enables ease of PC board layout
16.5 .650
Common
Coil 1 Open Space Coil 2
mm inch
SPECIFICATIONS
Contact
Arrangement Contact material Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact voltage drop, max. Nominal switching capacity Max. switching power Max. switching voltage Rating Max. make current 1 Form Cx2 (H bridge) Silver alloy 50 m
Characteristics
Max. operating speed (at rated load) Initial insulation resistance*1 Initial breakdown voltage*2
3
6 cpm Min. 100 m (at 500 V DC) 1,000 Vrms for 1 min. 1,000 Vrms for 1 min. Max. 10 ms Max. 10 ms Min. 100 m/s2 {10 G} Min. 1,000 m/s2 {100 G} Approx. 44.1 m/s2 {4.5 G}, 10 to 100 Hz Approx. 44.1 m/s2 {4.5 G}, 10 to 500 Hz -40C to + 85C -40F to +185F 5 to 85%R.H. Approx. 15 g .529 oz
0.2 V (at 20 A switching) N.O.: 20A 14 V DC N.C.: 10A 14 V DC 140 W 16 V DC 10 A (Continuous), 30 A (within 1 min.; coil applied voltage: 12 V, at 20C) 30 A (2 minutes ), 20A (1 hour) Max. carrying current (coil applied voltage: 12 V, at 20C) Mechanical (at 180 cpm) 106 resistive load Min.105 Expect 7 A 14 V DC, ed life Inrush 30 A 2x105 (min. Electrical (Motor load) ope.) 20 A 14 V DC Min.5x104 (Motor lock)
Between open contacts Between contacts and coil
Operate time* (at nominal voltage) Release time (without diode)*3 (at nominal voltage) Functional*4 Shock resistance Destructive*5 Vibration resistance Conditions for operation, transport and storage*7 (Not freezing and condensing at low temperature) Unit weight Functional*6 Destructive Ambient temp.
Humidity Standard type
Coil
Nominal operating power Remarks
* Specifications will vary with foreigh standards certification ratings. *1 Measurement at same location as "Intial breakdown voltage" section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms; detection time: 10s
640 mW
*5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10s *7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61)
TYPICAL APPLICATIONS
* Automotive: Power-window, power sunroof, etc.
ORDERING INFORMATION
Ex. CF Contact arrangement 1 Form C x 2 2 - 12 V Coil voltage(DC) 12 V
Standard packing: Carton: 35pcs.; Case: 700pcs.
367
CF
TYPES AND COIL DATA (at 20C 68F)
Part No. CF2-12V Nominal voltage, V DC 12 Pick-up voltage, V DC (max.) 7.2 Drop-out voltage, V DC (min.) 1.0 Coil resistance, (10%) 225 Nominal operating current, mA (10%) 53.3 Nominal operating Power, mW 640 Usable voltage range, VDC 10 to 16 mm inch
DIMENSIONS
Recommended PC board pattern
16.5 .650 (6-4 dia.) (6-.157 dia.) Land diameter 1.2 max. .047 max. 12.70.1 .500.004 0.3 .012 0.3 .012 0.3 .012 1 .039 12.7 .500 16.5 .650 3.81 .150 7.62 10.16 .300 .400 22.5 .886 5.08 .200 2.54 .100 5.08 .200 1.1 .043 6.350.1 .250.004 8-1.5 dia.0.1 8-.059 dia..004 (0.8) (.031) 3.810.1 .150.004
(R1.5) 1.270.1 .050.004 5.080.1 .200.004 2.540.1 .100.004 (3) 5.080.1 (.118) .200.004
3.5 .138
7.620.1 10.160.1 .300.004 .400.004
Schematic
N.O. COM1 N.C. COM2
1.1 .043
0.4 .016 1.1 .043
1.1 .043 0.4 .016
Dimension: Max. 1mm .039 inch: 1 to 3mm .039 to .118 inch: Min. 3mm .118 inch:
General tolerance 0.1 .004 0.2 .008 0.3 .012
EXAMPLE OF CIRCUITS
Forward/reverse control circuits of DC motor for power window
N.O. COM 12 V DC N.C.
M
N.O. COM N.C.
SW A
SW B M : Power window motor
SW A OFF ON OFF
SW B OFF OFF ON
Motor Stop Forward Reverse
368
CF
REFERENCE DATA
1-(1). Coil temperature rise (at 23C 73F)
Tested sample: CF2-12V, 6pcs. Contact carrying current: 0A, 7A, 10A, 15A, 20A
1-(2). Coil temperature rise (at 85C 185F)
Tested sample: CF2-12V, 6pcs. Contact carrying current: 10A, 15A, 20A
100
2-(1). Electrical life test (Motor lock)
Tested sample: CF2-12V, 3pcs. Load: 20A 14V DC Operating frequency: ON 1s, OFF 5s
10
Contact welding: 0 times Miscontact: 0 times
100 90
Pick-up and drop-out voltage, V
20 A Temperature rise, C 80 20A 15A 60 10A
8
Temperature rise, C
80 70 60 50 40 30 20 10 0 12 14
15 A 10 A 7A 0A
Pick-up voltage
6
Max. X Min.
40
4
Drop-out voltage
20
2
Max. X Min.
16
0
Coil applied voltage, V
12
14
16
0
0
5
Coil applied voltage, V
No. of operations, x104
2-(2). Electrical life test (Motor free)
Tested sample: CF2-12V, 3pcs. Load: 7A steady, Inrush 30A, 14V DC Operating frequency: ON 1s, OFF 5s
Sample 10
Contact welding: 0 times Miscontact: 0 times
Pick-up and drop-out voltage, V
8
Pick-up voltage
6
M
Max. X Min.
4
Drop-out voltage
2
Max. X Min.
0
0
10
20
No. of operations, x104
For Cautions for use, see Relay Technical Information (Page 48 to 76).
9/1/2000
All Rights Reserved, (c) Copyright Matsushita Electric Works, 369 Ltd.
Go To Online Catalog


▲Up To Search▲   

 
Price & Availability of CF2-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X